Need a compact, lightweight pump for small tasks?
These convenient
KNF filtration pumps are oil-free, lightweight and easy to use
for your disposable bottletop and flask filtration, vacuum manifold, blotting and desiccation
applications. Stop polluting drinking water and replace that water aspirator now. |

KNF filtration pumps are available with
or without a gauge package. |
| Filtration Pump Selection Guide Descriptive
Flyer |
| Disposable Bottletop
Filtration Units: For sterilizing tissue culture media, microbiological media, and other
biological solutions. |
 |
Pump Model
(click on link for datasheet)
|
Flow Rate |
End Vacuum |
Regulator/Gauge Pkg |
|
UN86KT.45P |
5.5 LPM |
120 Torr (25.2"Hg) |
Vacuum |
|
UN86KTP |
5.5 LPM |
120 Torr (25.2"Hg) |
None |
|
UN811KV.45P |
13 LPM |
75 Torr (27"Hg) |
Vacuum |
|
UN811KVP |
13 LPM |
75 Torr (27"Hg) |
None |
| Disposable
Filtration Assemblies: For sterilizing tissue culture media, microbiological media, and other
biological solutions. |
 |
Pump Model
(click on link for datasheet) |
Flow Rate
|
End Vacuum |
Regulator/Gauge Pkg |
|
UN86KT.45P |
5.5 LPM |
120 Torr (25.2 "Hg) |
Vacuum |
|
UN86KTP |
5.5 LPM |
120 Torr (25.2 "Hg) |
None |
|
UN811KV.45P |
13 LPM |
75 Torr (27 "Hg) |
Vacuum |
|
UN811KVP |
13 LPM |
75 Torr (27 "Hg) |
None |
| Manifold
Filtration: For multiple sample (3 and 6 place) sterility testing of antibiotics
and pharmaceuticals by bacteria retentive method and for routine microbiological
filtrations. Because of the potentially large volumes of liquid used with
vacuum manifolds, a liquid pre-trap is recommended. |
 |
Pump Model
(click on link for datasheet) |
Flow Rate |
End Vacuum |
Regulator/Gauge Pkg |
|
UN816.1.2KT.45P |
30 LPM |
120 (25.2 "Hg) |
Vacuum |
|
UN816.1.2KTP |
30 LPM |
120 Torr (25.2 "Hg) |
None |
| UN838.1.2KT.45P |
37 LPM |
113 Torr (25.7 "Hg) |
Vacuum |
| UN838.1.2KTP |
37 LPM |
113 Torr (25.7
"Hg) |
None |
| Glass
Filtration Assemblies: For filtration of aqueous, organic or corrosive liquids for
particulate contamination analysis and for HPLC solvent filtration or solid-phase extraction. |
 |
Pump Model
(click on link for datasheet) |
Flow Rate |
End Vacuum |
Regulator/Gauge Pkg |
|
UN811KV.45P |
13 LPM |
75 Torr (27 "Hg) |
Vacuum |
|
UN811KVP |
13 LPM |
75 Torr (27 "Hg) |
None |
|
UN816.1.2KT.45P |
30 LPM |
120 Torr (25.2 "Hg) |
Vacuum |
|
UN816.1.2KTP |
30 LPM |
120 Torr (25.2 "Hg) |
None |
| Solvent
Filtration and Degassing: For transferring solvents directly from the reagent bottle while removing
particulate from HPLC mobile phase. Once the filtration is complete, the
sample can then be degassed in the same vessel. |
 |
Pump Model
(click on link for datasheet) |
Flow Rate |
End Vacuum |
Regulator/Gauge Pkg |
|
UN816.3KT.45P |
16 LPM |
15 Torr (29.3 "Hg) |
Vacuum |
|
UN816.3KTP |
16 LPM |
15 Torr (29.3 "Hg) |
None |
| UN838.3KT.45P |
22 LPM |
11 Torr (29.5
"Hg) |
Vacuum |
| UN838.3KTP |
22 LPM |
11 Torr (29.5 "Hg) |
None |
| Desiccation: For
use in the removal of moisture in a sample preparation step or as an
anaerobic culture jar in bacteriological work. |
 |
Pump Model
(click on link for datasheet) |
End Vacuum |
Regulator/Gauge Pkg |
|
UN816.3KT.45P |
16 LPM |
15 Torr (29.3 "Hg) |
Vacuum |
|
UN816.3KTP |
16 LPM |
15 Torr (29.3 "Hg) |
None |
|
Pressure Filtration Applications |
 |
Pump Model
(click on link for datasheet) |
Flow Rate |
Max Pressure |
Regulator/Gauge Pkg |
|
UN86KT.46P |
5.5 LPM |
35 psig |
Pressure |
|
UN86KTP |
5.5 LPM |
35 psig |
None |
 |
|
|
|
| Complete
List of Filtration Pumps |
Pump Model
(click on link for datasheet) |
Flow Rate |
End Vacuum |
Max
Pressure |
Gauge Pkg |
Materials |
|
UN86KTP |
5.5 LPM |
120 Torr (25.2 "Hg) |
35
psig |
None |
PPS/PTFE/FFPM |
|
UN86KT.45P |
5.5 LPM |
120 Torr (25.2 "Hg) |
35
psig |
Vacuum |
PPS/PTFE/FFPM |
|
UN86KT.46P |
5.5 LPM |
120 Torr (25.2 "Hg) |
35
psig |
Pressure |
PPS/PTFE/FFPM |
| UN811KVP |
13
LPM |
75
Torr (27 "Hg) |
15
psig |
None |
PPS/EPDM |
| UN811KV.45P |
13 LPM |
75 Torr (28 "Hg) |
15 psig |
Vacuum |
PPS/PTFE/FPM |
| UN811KV.46P |
13 LPM |
75
Torr (28 "Hg) |
15 psig |
Pressure |
PPS/PTFE/FPM |
|
UN816.3KTP |
16 LPM |
15 Torr (29.3 "Hg) |
7.4
psig |
None |
PPS/PTFE/FFPM |
|
UN816.3KT.45P |
16 LPM |
15 Torr (29.3 "Hg) |
7.4
psig |
Vacuum |
PPS/PTFE/FFPM |
| UN816.1.2KTP |
30
LPM |
120
Torr (25.2 "Hg) |
7.4
psig |
None |
PPS/PTFE/FFPM |
| UN838.3KT.45P |
22 LPM |
11 Torr (29.5
"Hg) |
7.4 psig |
Vacuum |
PPS/PTFE/FFPM |
| UN838.3KTP |
22 LPM |
11 Torr (29.5 "Hg) |
7.4 psig |
None |
PPS/PTFE/FFPM |
|
UN816.1.2KT.45P |
30 LPM |
120 Torr (25.2 "Hg) |
7.4
psig |
Vacuum |
PPS/PTFE/FFPM |
| UN838.1.2KT.45P |
37 LPM |
113 Torr (25.5 "Hg) |
7.4 psig |
Vacuum |
PPS/PTFE/FFPM |
| UN838.1.2KTP |
37 LPM |
113 Torr (25.5 "Hg) |
7.4 psig |
None |
PPS/PTFE/FFPM |
|
|
Chemical Resistance Chart: |
|
|
NOTES: Standard continuous performance
ratings listed on this KNF website and on KNF datasheets are
based on technical data and test results of nominal units at
sea level, measured with an ambient temperature of 70°F
(21°C), and nominal
electrical supply as listed above, and are for reference only.Multiple-head
models, different performance models, cost-effective OEM modifications, and
a variety of motor options and different materials of construction are also
available. Certified drawings are available upon request. Specifications subject
to change without notice. You should always check corrosion resistance charts
for compatibility with the medium you intend to pump.
|
  |
KNF
NEUBERGER, INC.
Two Black Forest Road
Trenton, New Jersey 08691-1810
609-890-8600 • Fax 609-890-8323 • site
map
Copyright © 2013 by KNF Neuberger,
Inc. All rights reserved.
|


|